Drawing: RCT001/1 EOS Drawing: Motor: "good quality" DC servo with analog tachometer output. Velocity encoder:BEI Motor Encoder: incremental with index Overall encoder: Heidenhain RON 806 36,000 line count EXE 660 exploder connected and exploder 400:1 Limits: two-level East and West. -108 to +175 degrees feasable -80 to +160 degress because cables -78 to +158 safe the normal limits are for channel 1, the FS limits are channel2 HA Controller: PMAC#1 HA Drive Amplifier: Amp 1 Copley (413) Scale: 160,000 ppdeg. Home corr: is closed west (light is on) very close to meridian Home pulse: 6.65 west Slew: 1 degree per second 0.1 deg/sec/sec acc. Gear: 480 tooth
With a 3600 line encoder this give Scale: 19200.0 pulses pere degree
Jan 17,2023: measured change to using the HA axis encoder Measured: 19199.92 ppdeg
These encoders have a failure report. Two-level limits means an inner one that is used by the software and an outer one that does something more drastic.
Drawing: RCT001/1 EOS Drawing: Limits: two-level East and West. the normal limits are for channel 1, the FS limits are channel2 HA Preload: PMAC#2 HA Drive Amplifier: Amp 1 Copley (413) Preload Drive Amplifier: Amp 2 Encoder: 3600 line BEI (14400 pulses/turn)Software
rtel point command
rtel offset command rtel preload commandPhotos